PG thread chart
The PG thread (Panzergewinde) is a German conduit thread with an 80° flank angle and a shallow profile. It's still found on many cable glands, enclosures and replacement parts, although new designs mostly use metric threads to EN 60423.
- Standard
- DIN 40430
- Flank angle
- 80°
- Pitches
- 1.270 · 1.411 · 1.588 mm
- Sizes
- PG 7–48
PG thread sizes
All values in mm. Through-hole is the recommended clearance hole in the enclosure wall.
| Size | Outside Ø d | Core Ø d1 | Pitch P | Threads / inch | Through-hole |
|---|---|---|---|---|---|
| PG 7 | 12.50 | 11.28 | 1.270 | 20 | 12.7 |
| PG 9 | 15.20 | 13.86 | 1.411 | 18 | 15.4 |
| PG 11 | 18.60 | 17.26 | 1.411 | 18 | 18.8 |
| PG 13.5 | 20.40 | 19.06 | 1.411 | 18 | 20.7 |
| PG 16 | 22.50 | 21.16 | 1.411 | 18 | 22.8 |
| PG 21 | 28.30 | 26.78 | 1.588 | 16 | 28.6 |
| PG 29 | 37.00 | 35.48 | 1.588 | 16 | 37.4 |
| PG 36 | 47.00 | 45.48 | 1.588 | 16 | 47.5 |
| PG 42 | 54.00 | 52.48 | 1.588 | 16 | 54.5 |
| PG 48 | 59.30 | 57.78 | 1.588 | 16 | 59.8 |
Values to DIN 40430. Through-hole values are recommendations for the enclosure wall.
PG to metric conversion
Common metric replacements; where a PG size falls between two metric sizes, both are given. Always check the enclosure hole and the cable clamping range.
| PG size | PG outside Ø | Metric replacement (EN 60423) |
|---|---|---|
| PG 7 | 12.5 | M12×1.5 |
| PG 9 | 15.2 | M16×1.5 |
| PG 11 | 18.6 | M20×1.5 |
| PG 13.5 | 20.4 | M20×1.5 |
| PG 16 | 22.5 | M20×1.5 or M25×1.5 |
| PG 21 | 28.3 | M25×1.5 or M32×1.5 |
| PG 29 | 37.0 | M40×1.5 |
| PG 36 | 47.0 | M50×1.5 |
| PG 42 | 54.0 | M50×1.5 or M63×1.5 |
| PG 48 | 59.3 | M63×1.5 |