DIN 40430

PG thread chart

The PG thread (Panzergewinde) is a German conduit thread with an 80° flank angle and a shallow profile. It's still found on many cable glands, enclosures and replacement parts, although new designs mostly use metric threads to EN 60423.

Standard
DIN 40430
Flank angle
80°
Pitches
1.270 · 1.411 · 1.588 mm
Sizes
PG 7–48
P 80° t d d1
d outside Ø · d1 core Ø · P pitch · t thread depth = (d − d1) / 2 ≈ 0.48 P · crests and roots rounded

PG thread sizes

All values in mm. Through-hole is the recommended clearance hole in the enclosure wall.

SizeOutside Ø dCore Ø d1Pitch PThreads / inchThrough-hole
PG 712.5011.281.2702012.7
PG 915.2013.861.4111815.4
PG 1118.6017.261.4111818.8
PG 13.520.4019.061.4111820.7
PG 1622.5021.161.4111822.8
PG 2128.3026.781.5881628.6
PG 2937.0035.481.5881637.4
PG 3647.0045.481.5881647.5
PG 4254.0052.481.5881654.5
PG 4859.3057.781.5881659.8

Values to DIN 40430. Through-hole values are recommendations for the enclosure wall.

PG to metric conversion

Common metric replacements; where a PG size falls between two metric sizes, both are given. Always check the enclosure hole and the cable clamping range.

PG sizePG outside ØMetric replacement (EN 60423)
PG 712.5M12×1.5
PG 915.2M16×1.5
PG 1118.6M20×1.5
PG 13.520.4M20×1.5
PG 1622.5M20×1.5 or M25×1.5
PG 2128.3M25×1.5 or M32×1.5
PG 2937.0M40×1.5
PG 3647.0M50×1.5
PG 4254.0M50×1.5 or M63×1.5
PG 4859.3M63×1.5

Choice depends on the enclosure hole and the gland range. Adapters and reducers join PG and metric entries.