1. Home
  2. Resources
  3. Cable gland selection
Guide · EN 60423 · DIN 40430 · IEC 60529

How to select a cable gland

A cable gland has to fit three things: the entry in the enclosure, the outside diameter of the cable and the conditions where it is installed. Work through them in that order and the size and type follow.

Updated  · AirGrip, Jamnagar

1. The entry thread

SystemStandardPitchWhere you find it
MetricEN 604231.5 mmNew enclosures and machines, Europe and most export equipment
PGDIN 404301.270–1.588 mmOlder German and European equipment, replacement parts
NPTASME B1.20.1taper 1:16Equipment for the USA and Canada

PG and metric are not interchangeable even where the diameters are close: PG 13.5 is 20.4 mm across with an 80° thread, M20×1.5 is 20.0 mm with a 60° thread. The usual metric replacement for each PG size is on the PG thread chart.

2. The hole

Clearance holes for glands held with a lock nut.

MetricHole Ø
M12×1.512.5
M16×1.516.5
M20×1.520.5
M25×1.525.5
M32×1.532.5
M40×1.540.5
M50×1.550.5
M63×1.563.5
PGHole Ø
PG 712.7
PG 915.4
PG 1118.8
PG 13.520.7
PG 1622.8
PG 2128.6
PG 2937.4
PG 3647.5
PG 4254.5
PG 4859.8

Metric holes as tabulated in EN 50262 (tolerance +0.2 / −0.4 mm); PG holes from the PG thread chart. Values in mm. Check the gland maker's installation data for the final size.

In a clearance hole the gland is held by a lock nut on the inside. In a wall thick enough to tap, the thread is cut into the wall instead (tap drill for metric: d − 1.5, see the metric thread chart) and no lock nut is needed. Either way, the entry thread must be long enough for the wall plus the lock nut.

3. The cable

Gland size follows the outside diameter of the cable sheath, not the conductor cross-section: two 4 mm² cables from different makers can differ by several millimetres. Measure the sheath with calipers at two or three points and in two directions, because cables are rarely perfectly round.

Pick the gland whose clamping range covers that diameter with some margin at both ends. A cable at the very bottom of the range may not seal or hold; one at the top makes assembly hard and can damage the sheath.

Armoured cable needs a gland that terminates the armour; that is a different gland type. For flexible cable that moves near the entry, a strain-relief gland protects it from bending at the gland. A clamping-jaw gland grips the cable centrally and holds it against pull-out. Send us the cable's outside diameter with your enquiry and we propose the size.

4. The IP rating

IEC 60529: first digit solids, second digit water.

CodeDustWater
IP54Dust-protectedSplashing water from any direction
IP65Dust-tightWater jets
IP66Dust-tightPowerful water jets
IP67Dust-tightTemporary immersion (up to 1 m, 30 minutes)
IP68Dust-tightContinuous immersion, under conditions stated by the maker

The rating applies to the assembled joint: gland, seal, cable within the clamping range, and the seal between gland and enclosure. Our brass glands have an EPDM seal and are rated IP54. Where a location needs IP66 or IP68, specify a gland tested to that code.

5. Material and approvals

Brass is strong, machines to accurate threads and conducts, so the gland can be bonded to earth with an earth tag. It is used natural, or nickel-plated for a harder-wearing, corrosion-resistant surface. Plastic glands are lighter and cheaper for light-duty uses; stainless steel is chosen for food, chemical and marine environments.

Hazardous areas (Ex, ATEX, IECEx) need glands certified for the zone and protection type. Our glands are not certified for hazardous areas.

Lead. Our glands are made from CW614N brass under RoHS exemption 6(c), valid until 30 June 2027; lead-free CW724R is available on request. See lead-free and DZR brass.

Accessories you may need

Questions

What size hole is needed for an M20 cable gland?
20.5 mm for a clearance hole with a lock nut (EN 50262 table, tolerance +0.2 / −0.4 mm). For a tapped wall, drill 18.5 mm and tap M20×1.5.
How do I measure a cable for a gland?
Measure the outside diameter of the sheath with calipers at two or three points and in two directions, then choose a gland whose clamping range covers that diameter with margin at both ends.
Is PG 13.5 the same as M20?
No. PG 13.5 is 20.4 mm across with an 80° thread and 1.411 mm pitch; M20×1.5 is 20.0 mm with a 60° thread. M20×1.5 is the usual replacement; an adapter joins the two.
What does IP68 mean for a cable gland?
Dust-tight and protected against continuous immersion in water, under depth and time conditions stated by the gland maker (IEC 60529). It applies only with the cable inside the clamping range and the entry seal fitted.
Do I need a lock nut?
Yes, in a clearance hole. In a tapped wall the gland screws into the wall and a lock nut is not needed.
Are brass cable glands suitable for hazardous areas?
Only glands certified for the zone (Ex, ATEX or IECEx). Ours are not certified for hazardous areas.

Related

Need glands or accessories?

Tell us the entry thread and the cable outside diameter; we propose the size and send a quote.